LFY-607 Radiation heat conduction tester
The main purpose
It can be used to measure the thermal radiation resistance of single or multilayer fabrics in high temperature environment, and it can also be used to measure the thermal insulation performance of other fire-retardant panels. Anti-heat radiation performance is an important performance index of flame-retardant products. The accurate measurement of its protective performance has important guiding significance for selecting materials, researching and developing new products, and improving processing technology. This instrument fills the domestic gap.
Instrument characteristics
According to the ISO 6942-2002 (EN366) standard, the protection of materials can be tested according to two test methods. The first method (Method A) is that the sample is subjected to a certain amount of thermal radiation. In order to reproduce the harsh conditions of the material, record Changes in appearance. The second method (Method B) is to place a calorimeter on the back of the sample, heat is conducted from the back of the sample, and record the trend of temperature changes over time to determine the level of heat radiation transfer.
Main Specifications
1. Heating power of silicon carbide rod: 6.5kW/220V/50Hz, heating part length is 178mm, diameter is 8mm;
2、Range of heat flux density testing for heat sourcesRange of heat flux density testing for heat sources:5kW/m2~80 kW/m2(Test points:5 kW/m2、10 kW/m2、20 kW/m2、40 kW/m2、80 kW/m2)
3. Temperature control of heat radiation source: normal temperature~1200℃±5℃ (display accuracy is 1℃);
4. Thermal radiation source temperature sensor: thermocouple (0~1600℃);
5. Thermal radiation source temperature thermostat: with PID intelligent adjustment controller;
6. The heat capacity of the calorimeter: the actual measurement is about 480.937 J/K, and the heating area is (50×50) mm2;
7. The temperature measurement range of the calorimeter: normal temperature~80℃; temperature sensor Pt100 platinum resistance (-200~450℃);
8. Operating platform: Chinese Windows xp operating system, data output: t1, t2, t3, qc, TF and its average value;
9. Circulating water pump: HQB-3900/100W/220V/50Hz;
10. Air source: Mini air compressor, power 1/4HP 220V/50Hz;
11. Test environment: between 15℃~35℃, there should be no air circulation in the room.
Standards compliant
ISO 6942-2002 Protective clothing. Test methods for heat and fire protection clothing. Evaluation of materials and material components when affected by radiant heat sources
GB 38453-2019 Protective clothing一Protective clothing against heat Appendix B
GB 8965.2-2022 Protective clothing-Protective clothing for welders
GB 8965.3-2022 Protective clothing —Clothing to protect against molten metal splash