The main purpose
It is suitable for determining whether building materials are flammable under specified conditions.
Technical index
1. Nozzle aperture: ¢(0.17+0.03)mm
2. Flame height: (20±1) mm
3. Ignition timer: 0~99.99 seconds arbitrarily set
4. Use gas: propane gas with a purity of 95% or more
5. Sample size: 250mm×90mm
6. Ignition positioning device
7. Sample holder for melting and dripping products
Applicable standards (for different standards, different accessories are required)
GB/T 8626-2007 Test method for flammability of building materials
ISO 11925-2: 2002
Key words
Flame retardant tester, flame retardant tester for building materials, flame retardant tester for building materials
DIN 53438-2 Testing of combustible materials; response to ignition by a small flame; edge ignition
DIN 53438-3 Testing of combustible materials; response to ignition by a small flame; surface ignition