The main purpose
It is suitable for the evaluation of the horizontal combustion characteristics of leather materials.
Technical index
1. Sample ignition time: 15s;
2. The distance from the bottom of the sample to the bottom of the combustion chamber: 178mm;
3. The distance between the front end of the sample holder and the inner surface of the combustion box: 22mm;
4. The distance between the two longitudinal outer sides of the test bracket and the inner surface of the combustion box: 50mm;
5. The inner diameter of the nozzle: φ9.5mm;
6. Time setting range: 0~9999.9s; resolution: 0.1s.
Applicable standards
QB /T 2729-2005 Determination of the physical and mechanical properties of leather