Technical index
1. The water resistivity calibrated to 20℃ is the resistivity: (100±15)Ω·m.
2.The amount of rain is 1mm/min-2mm/min.
3. The two separated openings of the rain gauge are both 100-750cm3, and the depth is greater than or equal to half of the diameter.
4. The water storage tank can be pre-leached for 15 minutes.
5. The wet test time of AC and DC voltage is 60s.
6. Test voltage: 10kV, 20kV, 30kV, test time 3min.
7. The test needs to use voltage boost rate: 1000V/s, constant speed pressure.
Applicable standards (for different standards, different accessories are required)
GB/T 17622-2008, GB/T 16927.1